REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API SPEC 14L: Lock Mandrels and Landing Nipples : Reaffirmed

$

273

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 20F: Corrosion Resistant Bolting for Use in the Petroleum and Natural Gas Industries : Reaffirmed

$

169

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 5NCL Nickel Content Limits for API 5CT Sour Service Products

$

149

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 19ICD: Inflow Control Devices : Reaffirmed

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 23.2: Reconciliation of Liquid Tank Car(s) Quantities : Reaffirmed

$

218

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 16A: Specification for Drill-through Equipment

$

322

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-2: Field Testing Oil-based Drilling Fluids wA1

$

388

BUY NOW

ISO 19211:2024

ISO 19211:2024 Anaesthetic and respiratory equipment – Fire-activated oxygen shut-off devices for use during oxygen therapy

CDN $173.00

SKU: 6ca4e8814e73 Categories: ,

Description

This document specifies requirements for fire activated oxygen shut-off devices that stop the flow of oxygen in respiratory therapy tubing when activated by fire.

NOTE 1        Typical arrangements for fire activated oxygen shut-off devices are shown in Annex C.

NOTE 2        Respiratory therapy tubing is covered by ISO 17256.

NOTE 3        Use of fire activated oxygen shut-off devices in medical devices or accessories is not mandated in this document.

The fire activated oxygen shut-off devices specified in this document are not suitable for use with oxygen therapy systems with flows in excess of 20 l/min).

NOTE 4        There is rationale for this clause in A.2.

The requirements in this device-specific standard take precedence over any conflicting requirements in the general standard for airway devices (ISO 18190). All the common requirements that appear in the general standard for airway devices have been removed from this document.

Edition

1

Published Date

2024-08-30

Status

PUBLISHED

Pages

14

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies requirements for fire activated oxygen shut-off devices that stop the flow of oxygen in respiratory therapy tubing when activated by fire.

NOTE 1        Typical arrangements for fire activated oxygen shut-off devices are shown in Annex C.

NOTE 2        Respiratory therapy tubing is covered by ISO 17256.

NOTE 3        Use of fire activated oxygen shut-off devices in medical devices or accessories is not mandated in this document.

The fire activated oxygen shut-off devices specified in this document are not suitable for use with oxygen therapy systems with flows in excess of 20 l/min).

NOTE 4        There is rationale for this clause in A.2.

The requirements in this device-specific standard take precedence over any conflicting requirements in the general standard for airway devices (ISO 18190). All the common requirements that appear in the general standard for airway devices have been removed from this document.