This document is applicable for the determination of VOC and SVOC with an expected VOC and/or SVOC content greater than 0,01 % by mass up to 100 % by mass.
The method given in ISO 11890-1 is used when the VOC is greater than 15 % by mass. This document (method ISO 11890-2) applies when the system contains VOC and SVOC as the VOC result of ISO 11890-1 can be influenced by the SVOC. For VOC content smaller than 0,1 %, the head space method described in ISO 17895 is used as an alternative. ISO 11890-1 and ISO 17895 cannot be used for the determination of the SVOC content.
NOTE 1 Some ingredients of coating materials and their raw materials can decompose during analysis and cause artificial VOC and/or SVOC signals. When determining VOC and/or SVOC for coating materials and their raw materials, these signals are artefacts of the method and are not taken into account (examples are given in Annex B).
This method assumes that the volatile matter is either water or organic. However, other volatile inorganic compounds can be present and might need to be quantified by another suitable method and allowed for in the calculations. The method defined in this document is not applicable for determination of water content.
NOTE 2 If organic acids or bases and their corresponding salts are present in the coating material or its raw materials, the amount that is quantified by this method might not be accurate due to a change in the acid or base equilibrium.
Edition
4
Published Date
2020-06-23
Status
PUBLISHED
Pages
39
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
This document is applicable for the determination of VOC and SVOC with an expected VOC and/or SVOC content greater than 0,01 % by mass up to 100 % by mass.
The method given in ISO 11890-1 is used when the VOC is greater than 15 % by mass. This document (method ISO 11890-2) applies when the system contains VOC and SVOC as the VOC result of ISO 11890-1 can be influenced by the SVOC. For VOC content smaller than 0,1 %, the head space method described in ISO 17895 is used as an alternative. ISO 11890-1 and ISO 17895 cannot be used for the determination of the SVOC content.
NOTE 1 Some ingredients of coating materials and their raw materials can decompose during analysis and cause artificial VOC and/or SVOC signals. When determining VOC and/or SVOC for coating materials and their raw materials, these signals are artefacts of the method and are not taken into account (examples are given in Annex B).
This method assumes that the volatile matter is either water or organic. However, other volatile inorganic compounds can be present and might need to be quantified by another suitable method and allowed for in the calculations. The method defined in this document is not applicable for determination of water content.
NOTE 2 If organic acids or bases and their corresponding salts are present in the coating material or its raw materials, the amount that is quantified by this method might not be accurate due to a change in the acid or base equilibrium.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 80000:2019 Quantities and units – Part 11: Characteristic numbers
0 out of 5CDN $312.00 Add to cart -
ISO 10110:2019 Optics and photonics – Preparation of drawings for optical elements and systems – Part 1: General
0 out of 5CDN $312.00 Add to cart -
ISO 1176:1990 Road vehicles – Masses – Vocabulary and codes
0 out of 5CDN $115.00 Add to cart -
ISO 80004:2011 Nanotechnologies – Vocabulary – Part 7: Diagnostics and therapeutics for healthcare
0 out of 5CDN $115.00 Add to cart