ISO 14461:2005
ISO 14461:2005 Milk and milk products – Quality control in microbiological laboratories – Part 2: Determination of the reliability of colony counts of parallel plates and subsequent dilution steps
CDN $173.00
Description
ISO 14461-2|IDF 169-2:2005 describes a routine procedure for the evaluation of results of the enumeration of microorganisms using colony-count methods with subsequent 10-fold dilution steps and one plate or two parallel plates within each dilution step.
This routine procedure is applied regularly in each laboratory performing colony counts. It provides criteria for the acceptability of differences between the results from parallel plates and subsequent dilution steps, as follows.
The results (colony counts) obtained from parallel plates are compared with tabulated limits for given colony counts. If these limits are exceeded, a technical problem when performing the parallel determinations may be indicated.
The results (sums of colony counts) of two parallel plates of two subsequent 10-fold dilution steps are compared with tabulated limits for given sums of colony counts. If these limits are exceeded, a technical problem when performing the dilutions may be indicated.
If the limits mentioned above are exceeded in more cases than expected, this indicates that the test procedure lacks reliability.
Edition
1
Published Date
2005-04-12
Status
PUBLISHED
Pages
18
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
ISO 14461-2|IDF 169-2:2005 describes a routine procedure for the evaluation of results of the enumeration of microorganisms using colony-count methods with subsequent 10-fold dilution steps and one plate or two parallel plates within each dilution step.
This routine procedure is applied regularly in each laboratory performing colony counts. It provides criteria for the acceptability of differences between the results from parallel plates and subsequent dilution steps, as follows.
The results (colony counts) obtained from parallel plates are compared with tabulated limits for given colony counts. If these limits are exceeded, a technical problem when performing the parallel determinations may be indicated.
The results (sums of colony counts) of two parallel plates of two subsequent 10-fold dilution steps are compared with tabulated limits for given sums of colony counts. If these limits are exceeded, a technical problem when performing the dilutions may be indicated.
If the limits mentioned above are exceeded in more cases than expected, this indicates that the test procedure lacks reliability.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 16756:2024 Milk and milk products – Guidance for the application of Carr-Purcell-Meiboom-Gill (CPMG) pulsed time-domain nuclear magnetic resonance (TD-NMR) spectroscopy for fat determination
0 out of 5CDN $115.00 Add to cart -
ISO 20128:2006 Milk products – Enumeration of presumptive Lactobacillus acidophilus on a selective medium – Colony-count technique at 37 degrees C
0 out of 5CDN $115.00 Add to cart -
ISO 22935:2023 Milk and milk products – Sensory analysis – Part 1: Recruitment, selection, training and monitoring of assessors
0 out of 5CDN $173.00 Add to cart -
ISO 14891:2002 Milk and milk products – Determination of nitrogen content – Routine method using combustion according to the Dumas principle
0 out of 5CDN $173.00 Add to cart