Your cart is currently empty!

ISO 16773:2016
ISO 16773:2016 Electrochemical impedance spectroscopy (EIS) on coated and uncoated metallic specimens – Part 2: Collection of data
CDN $233.00
Description
ISO 16773-2:2016 gives guidelines for optimizing the collection of EIS data with focus on high-impedance systems. High impedance in the context of intact coatings refers to systems with an impedance greater than 109 Ω⋅cm2. This does not preclude measurements on systems with lower impedance. For uncoated samples extra information can be found in ISO/TR 16208.
ISO 16773-2:2016 deals with the following:
– instrumental set-up: requirements and pit-falls;
– data validation: checking the measurement range and the accuracy of the data;
– performing an EIS measurement: specimen considerations and instrumental parameters;
– the experimental results: different methods of presenting EIS data.
These guidelines are intended to ensure the acquisition of EIS data that can be used to study the performance of the specimen. This part of ISO 16773 does not give guidelines for the interpretation of the data.
Edition
2
Published Date
2016-03-30
Status
PUBLISHED
Pages
24
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
ISO 16773-2:2016 gives guidelines for optimizing the collection of EIS data with focus on high-impedance systems. High impedance in the context of intact coatings refers to systems with an impedance greater than 109 Ω⋅cm2. This does not preclude measurements on systems with lower impedance. For uncoated samples extra information can be found in ISO/TR 16208.
ISO 16773-2:2016 deals with the following:
- instrumental set-up: requirements and pit-falls;
- data validation: checking the measurement range and the accuracy of the data;
- performing an EIS measurement: specimen considerations and instrumental parameters;
- the experimental results: different methods of presenting EIS data.
These guidelines are intended to ensure the acquisition of EIS data that can be used to study the performance of the specimen. This part of ISO 16773 does not give guidelines for the interpretation of the data.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 8130:2019 Coating powders – Part 14: Vocabulary
0 out of 5CDN $76.00 Add to cart -
ISO 23496:2019 Determination of pH value – Reference buffer solutions for the calibration of pH measuring equipment
0 out of 5CDN $173.00 Add to cart -
ISO 9514:2019 Paints and varnishes – Determination of the pot life of multicomponent coating systems – Preparation and conditioning of samples and guidelines for testing
0 out of 5CDN $76.00 Add to cart -
ISO 23497:2019 Determination of pH value – Technical buffer solutions for the calibration of technical measuring installations
0 out of 5CDN $115.00 Add to cart