ISO 16911:2013
ISO 16911:2013 Stationary source emissions – Manual and automatic determination of velocity and volume flow rate in ducts – Part 1: Manual reference method
CDN $390.00
Description
ISO 16911-1:2013 specifies a method for periodic determination of the axial velocity and volume flow rate of gas within emissions ducts and stacks. It is applicable for use in circular or rectangular ducts with measurement locations meeting the requirements of EN 15259. Minimum and maximum duct sizes are driven by practical considerations of the measurement devices described within ISO 16911-1:2013.
ISO 16911-1:2013 requires all flow measurements to have demonstrable metrological traceability to national or international primary standards.
To be used as a standard reference method, the user is required to demonstrate that the performance characteristics of the method are equal to or better than the performance criteria defined in ISO 16911-1:2013 and that the overall uncertainty of the method, expressed with a level of confidence of 95 %, is determined and reported. The results for each method defined in ISO 16911-1:2013 have different uncertainties within a range of 1 % to 10 % at flow velocities of 20 m/s.
Methods further to these can be used provided that the user can demonstrate equivalence, based on the principles of CEN/TS 14793.
Edition
1
Published Date
2013-03-01
Status
PUBLISHED
Pages
84
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
ISO 16911-1:2013 specifies a method for periodic determination of the axial velocity and volume flow rate of gas within emissions ducts and stacks. It is applicable for use in circular or rectangular ducts with measurement locations meeting the requirements of EN 15259. Minimum and maximum duct sizes are driven by practical considerations of the measurement devices described within ISO 16911-1:2013.
ISO 16911-1:2013 requires all flow measurements to have demonstrable metrological traceability to national or international primary standards.
To be used as a standard reference method, the user is required to demonstrate that the performance characteristics of the method are equal to or better than the performance criteria defined in ISO 16911-1:2013 and that the overall uncertainty of the method, expressed with a level of confidence of 95 %, is determined and reported. The results for each method defined in ISO 16911-1:2013 have different uncertainties within a range of 1 % to 10 % at flow velocities of 20 m/s.
Methods further to these can be used provided that the user can demonstrate equivalence, based on the principles of CEN/TS 14793.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 21877:2019 Stationary source emissions- Determination of the mass concentration of ammonia – Manual method
0 out of 5CDN $312.00 Add to cart -
ISO 16911:2013 Stationary source emissions – Manual and automatic determination of velocity and volume flow rate in ducts – Part 2: Automated measuring systems
0 out of 5CDN $351.00 Add to cart -
ISO 12039:2019 Stationary source emissions – Determination of the mass concentration of carbon monoxide, carbon dioxide and oxygen in flue gas – Performance characteristics of automated measuring systems
0 out of 5CDN $351.00 Add to cart -
ISO 21741:2020 Stationary source emissions – Sampling and determination of mercury compounds in flue gas using gold amalgamation trap
0 out of 5CDN $273.00 Add to cart