REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API SPEC 14L: Lock Mandrels and Landing Nipples : Reaffirmed

$

273

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 20F: Corrosion Resistant Bolting for Use in the Petroleum and Natural Gas Industries : Reaffirmed

$

169

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 5NCL Nickel Content Limits for API 5CT Sour Service Products

$

149

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 19ICD: Inflow Control Devices : Reaffirmed

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 23.2: Reconciliation of Liquid Tank Car(s) Quantities : Reaffirmed

$

218

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 16A: Specification for Drill-through Equipment

$

322

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-2: Field Testing Oil-based Drilling Fluids wA1

$

388

BUY NOW

ISO 18250:2018

ISO 18250:2018 Medical devices – Connectors for reservoir delivery systems for healthcare applications – Part 7: Connectors for intravascular infusion

CDN $273.00

SKU: 83dfac09c1e5 Category:

Description

This document specifies the interface dimensions and requirements for the design and functional performance of connectors intended to be used to connect intravascular infusion sets to intravascular infusion reservoirs.

This document does not specify the dimensions and requirements for the medical devices or accessories that use these connectors. Such requirements are given in particular international standards for specific medical devices or accessories.

EXAMPLES Medical devices which may use intravascular reservoir connectors are the following:

– Administration ports on IV fluid reservoirs and the mating spikes of IV administration/intravascular infusion sets/lines, e.g., IV bags/containers and the spike inlet ends of IV sets;

– Devices intended to be connected in series between the administration port of IV fluid reservoirs and the mating spikes of IV administration/giving lines;

– Syringes and syringe IV sets utilizing Luer connectors.

The following connectors are excluded from the scope of this document:

– Stoppers for bottles as specified in ISO 8536-2;

– Compounding/admixture ports on IV reservoirs and intended mating devices.

EXAMPLES Rubber stoppers used for injection into the reservoir and the mating pharmacy admixture devices (syringes, needles, reconstitution devices, and other ancillary equipment used to access the compounding or admixture ports).

– The fill ports of non-powered (i.e. elastomeric) pumps.

NOTE 1 Details of alternative spikes that are in common use are located in Annex G for informational purposes.

NOTE 2 Manufacturers are encouraged to incorporate the connectors specified in this document into intravascular infusion medical devices or accessories, even if not currently required by the particular medical device standards. It is expected that when the particular medical device standards are revised, requirements for reservoir connectors, as specified in ISO 18250, will be included.

Edition

1

Published Date

2018-12-17

Status

PUBLISHED

Pages

34

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies the interface dimensions and requirements for the design and functional performance of connectors intended to be used to connect intravascular infusion sets to intravascular infusion reservoirs.

This document does not specify the dimensions and requirements for the medical devices or accessories that use these connectors. Such requirements are given in particular international standards for specific medical devices or accessories.

EXAMPLES Medical devices which may use intravascular reservoir connectors are the following:

- Administration ports on IV fluid reservoirs and the mating spikes of IV administration/intravascular infusion sets/lines, e.g., IV bags/containers and the spike inlet ends of IV sets;

- Devices intended to be connected in series between the administration port of IV fluid reservoirs and the mating spikes of IV administration/giving lines;

- Syringes and syringe IV sets utilizing Luer connectors.

The following connectors are excluded from the scope of this document:

- Stoppers for bottles as specified in ISO 8536-2;

- Compounding/admixture ports on IV reservoirs and intended mating devices.

EXAMPLES Rubber stoppers used for injection into the reservoir and the mating pharmacy admixture devices (syringes, needles, reconstitution devices, and other ancillary equipment used to access the compounding or admixture ports).

- The fill ports of non-powered (i.e. elastomeric) pumps.

NOTE 1 Details of alternative spikes that are in common use are located in Annex G for informational purposes.

NOTE 2 Manufacturers are encouraged to incorporate the connectors specified in this document into intravascular infusion medical devices or accessories, even if not currently required by the particular medical device standards. It is expected that when the particular medical device standards are revised, requirements for reservoir connectors, as specified in ISO 18250, will be included.

Previous Editions

Can’t find what you are looking for?

Please contact us at: