ISO 22335:2007 Surface chemical analysis – Depth profiling – Measurement of sputtering rate: mesh-replica method using a mechanical stylus profilometer
CDN $173.00
Description
ISO/TR 22335:2007 describes a method for determining ion-sputtering rates for depth profiling measurements with Auger electron spectroscopy (AES) and X‚Äëray photoelectron spectroscopy (XPS) where the specimen is ion-sputtered over a region with an area between 0,4 mm2 and 3,0 mm2. The Technical Report is applicable only to a laterally homogeneous bulk or single-layered material where the ion-sputtering rate is determined from the sputtered depth, as measured by a mechanical stylus profilometer, and sputtering time.
The Technical Report provides a method to convert the ion-sputtering time scale to sputtered depth in a depth profile by assuming a constant sputtering velocity. This method has not been designed for, or tested using, a scanning probe microscope system. It is not applicable to the case where the sputtered area is less than 0,4 mm2 or where the sputter-induced surface roughness is significant compared with the sputtered depth to be measured.
Edition
1
Published Date
2007-07-02
Status
PUBLISHED
Pages
18
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
ISO/TR 22335:2007 describes a method for determining ion-sputtering rates for depth profiling measurements with Auger electron spectroscopy (AES) and X‚Äëray photoelectron spectroscopy (XPS) where the specimen is ion-sputtered over a region with an area between 0,4 mm2 and 3,0 mm2. The Technical Report is applicable only to a laterally homogeneous bulk or single-layered material where the ion-sputtering rate is determined from the sputtered depth, as measured by a mechanical stylus profilometer, and sputtering time.
The Technical Report provides a method to convert the ion-sputtering time scale to sputtered depth in a depth profile by assuming a constant sputtering velocity. This method has not been designed for, or tested using, a scanning probe microscope system. It is not applicable to the case where the sputtered area is less than 0,4 mm2 or where the sputter-induced surface roughness is significant compared with the sputtered depth to be measured.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 80000:2019 Quantities and units – Part 11: Characteristic numbers
0 out of 5CDN $312.00 Add to cart -
ISO 80004:2020 Nanotechnologies – Vocabulary – Part 3: Carbon nano-objects
0 out of 5CDN $76.00 Add to cart -
ISO 20537:2025 Footwear – Identification of defects during visual inspection – Vocabulary
0 out of 5CDN $273.00 Add to cart -
ISO 1176:1990 Road vehicles – Masses – Vocabulary and codes
0 out of 5CDN $115.00 Add to cart