ISO 23471:2022
ISO 23471:2022 Experimental designs for evaluation of uncertainty – Use of factorial designs for determining uncertainty functions
CDN $233.00
Description
This document specifies experimental procedures and statistical analysis for the determination of measurement uncertainty in situations where the following conditions are fulfilled:
Condition 1: The level of the measurand is non-negative, e.g. concentration level of a contaminant in a sample.
Condition 2: Measurement error consists of two independent components: for one of these components the relative standard deviation is constant (that is, the absolute deviation is proportional to the level of the measurand), whereas for the other component the absolute standard deviation is constant (that is, independent of the level of the measurand).
Condition 3: Samples for different levels of the measurand can be made available; if the level of the measurand is the concentration of a chemical substance, samples could be obtained e.g. by fortifying (spiking) blank samples.
Conditions 1 and 2 are met for most applications of instrumental chemical analyses. Condition 3 can be met for chemical analyses if blank samples are available.
This document can also be used to determine precision data for a particular laboratory for different technicians, different environmental conditions, the same or similar test items, with the same level of the measurand, over a certain period of time.
Edition
1
Published Date
2022-11-07
Status
PUBLISHED
Pages
26
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
This document specifies experimental procedures and statistical analysis for the determination of measurement uncertainty in situations where the following conditions are fulfilled:
Condition 1: The level of the measurand is non-negative, e.g. concentration level of a contaminant in a sample.
Condition 2: Measurement error consists of two independent components: for one of these components the relative standard deviation is constant (that is, the absolute deviation is proportional to the level of the measurand), whereas for the other component the absolute standard deviation is constant (that is, independent of the level of the measurand).
Condition 3: Samples for different levels of the measurand can be made available; if the level of the measurand is the concentration of a chemical substance, samples could be obtained e.g. by fortifying (spiking) blank samples.
Conditions 1 and 2 are met for most applications of instrumental chemical analyses. Condition 3 can be met for chemical analyses if blank samples are available.
This document can also be used to determine precision data for a particular laboratory for different technicians, different environmental conditions, the same or similar test items, with the same level of the measurand, over a certain period of time.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 2859:2020 Sampling procedures for inspection by attributes – Part 2: Sampling plans indexed by limiting quality (LQ) for isolated lot inspection
0 out of 5CDN $312.00 Add to cart -
ISO 3534:2006 Statistics – Vocabulary and symbols – Part 2: Applied statistics
0 out of 5CDN $390.00 Add to cart -
ISO 13528:2022 Statistical methods for use in proficiency testing by interlaboratory comparison
0 out of 5CDN $390.00 Add to cart -
ISO 3951:2006 Sampling procedures for inspection by variables – Part 5: Sequential sampling plans indexed by acceptance quality limit (AQL) for inspection by variables (known standard deviation)
0 out of 5CDN $312.00 Add to cart