Your cart is currently empty!

ISO 3313:2018
ISO 3313:2018 Measurement of fluid flow in closed conduits – Guidelines on the effects of flow pulsations on flow-measurement instruments
CDN $312.00
Description
ISO/TR 3313:2018 defines pulsating flow, compares it with steady flow, indicates how it can be detected, and describes the effects it has on orifice plates, nozzles or Venturi tubes, turbine and vortex flowmeters when these devices are being used to measure fluid flow in a pipe. These particular flowmeter types feature in this document because they are amongst those types most susceptible to pulsation effects. Methods for correcting the flowmeter output signal for errors produced by these effects are described for those flowmeter types for which this is possible. When correction is not possible, measures to avoid or reduce the problem are indicated. Such measures include the installation of pulsation damping devices and/or choice of a flowmeter type which is less susceptible to pulsation effects.
ISO/TR 3313:2018 applies to flow in which the pulsations are generated at a single source which is situated either upstream or downstream of the primary element of the flowmeter. Its applicability is restricted to conditions where the flow direction does not reverse in the measuring section but there is no restriction on the waveform of the flow pulsation. The recommendations within this document apply to both liquid and gas flows although with the latter the validity might be restricted to gas flows in which the density changes in the measuring section are small as indicated for the particular type of flowmeter under discussion.
Edition
4
Published Date
2018-03-15
Status
PUBLISHED
Pages
45
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
ISO/TR 3313:2018 defines pulsating flow, compares it with steady flow, indicates how it can be detected, and describes the effects it has on orifice plates, nozzles or Venturi tubes, turbine and vortex flowmeters when these devices are being used to measure fluid flow in a pipe. These particular flowmeter types feature in this document because they are amongst those types most susceptible to pulsation effects. Methods for correcting the flowmeter output signal for errors produced by these effects are described for those flowmeter types for which this is possible. When correction is not possible, measures to avoid or reduce the problem are indicated. Such measures include the installation of pulsation damping devices and/or choice of a flowmeter type which is less susceptible to pulsation effects.
ISO/TR 3313:2018 applies to flow in which the pulsations are generated at a single source which is situated either upstream or downstream of the primary element of the flowmeter. Its applicability is restricted to conditions where the flow direction does not reverse in the measuring section but there is no restriction on the waveform of the flow pulsation. The recommendations within this document apply to both liquid and gas flows although with the latter the validity might be restricted to gas flows in which the density changes in the measuring section are small as indicated for the particular type of flowmeter under discussion.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 14164:1999 Stationary source emissions – Determination of the volume flowrate of gas streams in ducts – Automated method
0 out of 5CDN $173.00 Add to cart -
ISO 20456:2017 Measurement of fluid flow in closed conduits – Guidance for the use of electromagnetic flowmeters for conductive liquids
0 out of 5CDN $273.00 Add to cart -
ISO 2975:1975 Measurement of water flow in closed conduits – Tracer methods – Part 2: Constant rate injection method using non-radioactive tracers
0 out of 5CDN $115.00 Add to cart -
ISO 12764:2017 Measurement of fluid flow in closed conduits – Flowrate measurement by means of vortex shedding flowmeters inserted in circular cross-section conduits running full
0 out of 5CDN $233.00 Add to cart