Your cart is currently empty!

ISO 3951:2007
ISO 3951:2007 Sampling procedures for inspection by variables – Part 3: Double sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection
CDN $390.00
Description
ISO 3951-3:2007 specifies an acceptance sampling system of double sampling schemes for inspection by variables for percent nonconforming. It is indexed in terms of the acceptance quality limit (AQL).
The objectives of the methods laid down in ISO 3951-3:2007 are to ensure that lots of acceptable quality have a high probability of acceptance and that the probability of non-accepting inferior lots is as high as practicable. This is achieved by means of the switching rules, which provide automatic protection to the consumer (by means of a switch to tightened inspection or discontinuation of sampling inspection) should a deterioration in quality be detected, and an incentive (at the discretion of the responsible authority) to reduce inspection costs (by means of a switch to a smaller sample size) should consistently good quality be achieved.
In ISO 3951-3:2007, the acceptability of a lot is implicitly or explicitly determined from an estimate of the percentage of nonconforming items in the process, based on either one or two random samples of items from the lot.
ISO 3951-3:2007 is primarily designed for use under the following conditions: where the inspection procedure is to be applied to a continuing series of lots of discrete products all supplied by one producer using one production process; where the items of product have a single quality characteristic; where the quality characteristic is measurable on a continuous scale; where the measurement error is negligible (i.e. with a standard deviation no more than 10 % of the corresponding process standard deviation); where production is stable (under statistical control) and the quality characteristic is distributed, at least to a close approximation, according to a normal distribution; where the possibility of having to select and inspect a second sample is administratively acceptable; and where a contract or standard defines an upper specification limit, a lower specification limit, or both on the quality characteristic.
The procedures in ISO 3951-3:2007 are not suitable for application to lots that have been screened previously for nonconforming items.
Edition
1
Published Date
2007-04-26
Status
PUBLISHED
Pages
113
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
ISO 3951-3:2007 specifies an acceptance sampling system of double sampling schemes for inspection by variables for percent nonconforming. It is indexed in terms of the acceptance quality limit (AQL).
The objectives of the methods laid down in ISO 3951-3:2007 are to ensure that lots of acceptable quality have a high probability of acceptance and that the probability of non-accepting inferior lots is as high as practicable. This is achieved by means of the switching rules, which provide automatic protection to the consumer (by means of a switch to tightened inspection or discontinuation of sampling inspection) should a deterioration in quality be detected, and an incentive (at the discretion of the responsible authority) to reduce inspection costs (by means of a switch to a smaller sample size) should consistently good quality be achieved.
In ISO 3951-3:2007, the acceptability of a lot is implicitly or explicitly determined from an estimate of the percentage of nonconforming items in the process, based on either one or two random samples of items from the lot.
ISO 3951-3:2007 is primarily designed for use under the following conditions: where the inspection procedure is to be applied to a continuing series of lots of discrete products all supplied by one producer using one production process; where the items of product have a single quality characteristic; where the quality characteristic is measurable on a continuous scale; where the measurement error is negligible (i.e. with a standard deviation no more than 10 % of the corresponding process standard deviation); where production is stable (under statistical control) and the quality characteristic is distributed, at least to a close approximation, according to a normal distribution; where the possibility of having to select and inspect a second sample is administratively acceptable; and where a contract or standard defines an upper specification limit, a lower specification limit, or both on the quality characteristic.
The procedures in ISO 3951-3:2007 are not suitable for application to lots that have been screened previously for nonconforming items.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 16355:2023 Applications of statistical and related methods to new technology and product development process – Part 7: Guidelines for developing digitalized products and services – General principles and perspectives of the QFD method
0 out of 5CDN $233.00 Add to cart -
ISO 5725:2020 Accuracy (trueness and precision) of measurement methods and results – Part 4: Basic methods for the determination of the trueness of a standard measurement method
0 out of 5CDN $233.00 Add to cart -
ISO 2854:1976 Statistical interpretation of data – Techniques of estimation and tests relating to means and variances
0 out of 5CDN $312.00 Add to cart -
ISO 3951:2006 Sampling procedures for inspection by variables – Part 5: Sequential sampling plans indexed by acceptance quality limit (AQL) for inspection by variables (known standard deviation)
0 out of 5CDN $312.00 Add to cart