REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API SPEC 14L: Lock Mandrels and Landing Nipples : Reaffirmed

$

273

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 20F: Corrosion Resistant Bolting for Use in the Petroleum and Natural Gas Industries : Reaffirmed

$

169

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 5NCL Nickel Content Limits for API 5CT Sour Service Products

$

149

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 19ICD: Inflow Control Devices : Reaffirmed

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 23.2: Reconciliation of Liquid Tank Car(s) Quantities : Reaffirmed

$

218

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 16A: Specification for Drill-through Equipment

$

322

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-2: Field Testing Oil-based Drilling Fluids wA1

$

388

BUY NOW

ISO 4240:2023

ISO 4240:2023 Fine bubble technology – Environmental applications – Part 1: Inspection method using online particle counter in dissolved air flotation (DAF) plant

CDN $173.00

Description

This document specifies the bubble volume concentration and bubble bed depth measurement methods by online particle counter for checking DAF process performance in plant.

The test method of bubble volume concentration is made by measuring bubble size distribution in contact zone of DAF tank and calculating using formula. And bubble bed depth is evaluated by measuring the number of bubbles and particles according to the depth at five points in separation zone of DAF tank.

This document provides the advantages and limitations of using online particle counter in plant.

Edition

1

Published Date

2023-03-31

Status

PUBLISHED

Pages

18

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies the bubble volume concentration and bubble bed depth measurement methods by online particle counter for checking DAF process performance in plant.

The test method of bubble volume concentration is made by measuring bubble size distribution in contact zone of DAF tank and calculating using formula. And bubble bed depth is evaluated by measuring the number of bubbles and particles according to the depth at five points in separation zone of DAF tank.

This document provides the advantages and limitations of using online particle counter in plant.

Previous Editions

Can’t find what you are looking for?

Please contact us at: