ISO 4869:2018
ISO 4869:2018 Acoustics – Hearing protectors – Part 1: Subjective method for the measurement of sound attenuation
CDN $173.00
Description
This document specifies a subjective method for measuring sound attenuation of hearing protectors at the threshold of hearing. The method is a laboratory method designed to yield reproducible values under controlled measurement conditions. The values reflect the attenuating characteristics of the hearing protector only to the extent that users wear the device in the same manner as did the test subjects.
For a more representative indication of field performance the methods of ISO/TS 4869‚Äë5 can be used.
This test method yields data which are collected at low sound pressure levels (close to the threshold of hearing) but which are also representative of the attenuation values of hearing protectors at higher sound pressure levels. An exception occurs in the case of amplitude-sensitive hearing protectors for sound pressure levels above the point at which their level-dependent characteristics become effective. At those sound pressure levels the method specified in this document is inapplicable, as it will usually underestimate sound attenuation for these devices.
NOTE Due to masking from physiological noise in the occluded ear tests, sound attenuations below 500 Hz can be overestimated by a few decibels.
Edition
2
Published Date
2018-10-04
Status
PUBLISHED
Pages
18
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
This document specifies a subjective method for measuring sound attenuation of hearing protectors at the threshold of hearing. The method is a laboratory method designed to yield reproducible values under controlled measurement conditions. The values reflect the attenuating characteristics of the hearing protector only to the extent that users wear the device in the same manner as did the test subjects.
For a more representative indication of field performance the methods of ISO/TS 4869‚Äë5 can be used.
This test method yields data which are collected at low sound pressure levels (close to the threshold of hearing) but which are also representative of the attenuation values of hearing protectors at higher sound pressure levels. An exception occurs in the case of amplitude-sensitive hearing protectors for sound pressure levels above the point at which their level-dependent characteristics become effective. At those sound pressure levels the method specified in this document is inapplicable, as it will usually underestimate sound attenuation for these devices.
NOTE Due to masking from physiological noise in the occluded ear tests, sound attenuations below 500 Hz can be overestimated by a few decibels.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 1991:1982 Vegetables – Nomenclature – First list
0 out of 5CDN $115.00 Add to cart -
ISO 18662:2020 Traditional Chinese medicine – Vocabulary – Part 2: Processing of Chinese Materia Medica
0 out of 5CDN $76.00 Add to cart -
ISO 20537:2025 Footwear – Identification of defects during visual inspection – Vocabulary
0 out of 5CDN $273.00 Add to cart -
ISO 13666:2019 Ophthalmic optics – Spectacle lenses – Vocabulary
0 out of 5CDN $76.00 Add to cart