Your cart is currently empty!

ISO 51956:2013
ISO 51956:2013 Practice for use of a thermoluminescence-dosimetry system (TLD system) for radiation processing
CDN $115.00
Description
ISO/ASTM 51956:2013 covers procedures for the use of thermoluminescence dosimeters (TLDs) to measure the absorbed dose in materials irradiated by photons or electrons in terms of absorbed dose to water. Thermoluminescence-dosimetry systems (TLD systems) are generally used as routine dosimetry systems.
The thermoluminescence dosimeter (TLD) is classified as a type II dosimeter on the basis of the complex effect of influence quantities on the dosimeter response.
ISO/ASTM 51956:2013 is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ISO/ASTM 52628 “Practice for Dosimetry in Radiation Processing” for a TLD system.
It is intended to be read in conjunction with ISO/ASTM 52628.
Edition
3
Published Date
2013-11-05
Status
PUBLISHED
Pages
8
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
ISO/ASTM 51956:2013 covers procedures for the use of thermoluminescence dosimeters (TLDs) to measure the absorbed dose in materials irradiated by photons or electrons in terms of absorbed dose to water. Thermoluminescence-dosimetry systems (TLD systems) are generally used as routine dosimetry systems.
The thermoluminescence dosimeter (TLD) is classified as a type II dosimeter on the basis of the complex effect of influence quantities on the dosimeter response.
ISO/ASTM 51956:2013 is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ISO/ASTM 52628 "Practice for Dosimetry in Radiation Processing" for a TLD system.
It is intended to be read in conjunction with ISO/ASTM 52628.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 52900:2021 Additive manufacturing – General principles – Fundamentals and vocabulary
0 out of 5CDN $76.00 Add to cart -
ISO 52926:2023 Additive manufacturing of metals – Qualification principles – Part 3: Qualification of operators for PBF-EB
0 out of 5CDN $76.00 Add to cart -
ISO 51818:2020 Practice for dosimetry in an electron beam facility for radiation processing at energies between 80 and 300 keV
0 out of 5CDN $173.00 Add to cart -
ISO 51649:2015 Practice for dosimetry in an electron beam facility for radiation processing at energies between 300 keV and 25 MeV
0 out of 5CDN $273.00 Add to cart