Your cart is currently empty!

ISO 5725:2023
ISO 5725:2023 Accuracy (trueness and precision) of measurement methods and results – Part 3: Intermediate precision and alternative designs for collaborative studies
CDN $351.00
Description
This document provides
a)    a discussion of alternative experimental designs for the determination of trueness and precision measures including reproducibility, repeatability and selected measures of intermediate precision of a standard measurement method, including a review of the circumstances in which their use is necessary or beneficial, and guidance as to the interpretation and application of the resulting estimates, and
b)    worked examples including specific designs and computations.
Each of the alternative designs discussed in this document is intended to address one (or several) of the following issues:
a)    a discussion of the implications of the definitions of intermediate precision measures;
b)    a guidance on the interpretation and application of the estimates of intermediate precision measures in practical situations;
c)    determining reproducibility, repeatability and selected measures of intermediate precision;
d)    improved determination of reproducibility and other measures of precision;
e)    improving the estimate of the sample mean;
f)     determining the range of in-house repeatability standard deviations;
g)    determining other precision components such as operator variability;
h)    determining the level of reliability of precision estimates;
i)     reducing the minimum number of participating laboratories by optimizing the reliability of precision estimates;
j)     avoiding distorted estimations of repeatability (split-level designs);
k)    avoiding distorted estimations of reproducibility (taking the heterogeneity of the material into consideration).
Often, the performance of the method whose precision is being evaluated in a collaborative study will have previously been assessed in a single-laboratory validation study conducted by the laboratory which developed it. Relevant factors for the determination of intermediary precision will have been identified in this prior single-laboratory study.
Edition
2
Published Date
2023-06-28
Status
PUBLISHED
Pages
57
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
This document provides
a)    a discussion of alternative experimental designs for the determination of trueness and precision measures including reproducibility, repeatability and selected measures of intermediate precision of a standard measurement method, including a review of the circumstances in which their use is necessary or beneficial, and guidance as to the interpretation and application of the resulting estimates, and
b)    worked examples including specific designs and computations.
Each of the alternative designs discussed in this document is intended to address one (or several) of the following issues:
a)    a discussion of the implications of the definitions of intermediate precision measures;
b)    a guidance on the interpretation and application of the estimates of intermediate precision measures in practical situations;
c)    determining reproducibility, repeatability and selected measures of intermediate precision;
d)    improved determination of reproducibility and other measures of precision;
e)    improving the estimate of the sample mean;
f)     determining the range of in-house repeatability standard deviations;
g)    determining other precision components such as operator variability;
h)    determining the level of reliability of precision estimates;
i)     reducing the minimum number of participating laboratories by optimizing the reliability of precision estimates;
j)     avoiding distorted estimations of repeatability (split-level designs);
k)    avoiding distorted estimations of reproducibility (taking the heterogeneity of the material into consideration).
Often, the performance of the method whose precision is being evaluated in a collaborative study will have previously been assessed in a single-laboratory validation study conducted by the laboratory which developed it. Relevant factors for the determination of intermediary precision will have been identified in this prior single-laboratory study.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 3951:2006 Sampling procedures for inspection by variables – Part 5: Sequential sampling plans indexed by acceptance quality limit (AQL) for inspection by variables (known standard deviation)
0 out of 5CDN $312.00 Add to cart -
ISO 7870:2023 Control charts – Part 2: Shewhart control charts
0 out of 5CDN $312.00 Add to cart -
ISO 13528:2022 Statistical methods for use in proficiency testing by interlaboratory comparison
0 out of 5CDN $390.00 Add to cart -
ISO 3951:2023 Sampling procedures for inspection by variables – Part 6: Specification for single sampling plans for isolated lot inspection indexed by limiting quality (LQ)
0 out of 5CDN $351.00 Add to cart