REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API SPEC 14L: Lock Mandrels and Landing Nipples : Reaffirmed

$

273

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 20F: Corrosion Resistant Bolting for Use in the Petroleum and Natural Gas Industries : Reaffirmed

$

169

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 5NCL Nickel Content Limits for API 5CT Sour Service Products

$

149

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 19ICD: Inflow Control Devices : Reaffirmed

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 23.2: Reconciliation of Liquid Tank Car(s) Quantities : Reaffirmed

$

218

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 16A: Specification for Drill-through Equipment

$

322

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-2: Field Testing Oil-based Drilling Fluids wA1

$

388

BUY NOW

ISO 7240:2022

ISO 7240:2022 Fire detection and alarm systems – Part 12: Line type smoke detectors using a transmitted optical beam

CDN $351.00

SKU: 6415251d1c23 Categories: ,

Description

This document specifies requirements, test methods and performance criteria for line-type smoke detectors for use in fire detection systems installed in buildings. The detectors consist of at least a transmitter and a receiver and can include reflector(s) for the detection of smoke by the attenuation and/or changes in attenuation of an optical beam.

This document is not applicable to:

-    line-type smoke detectors designed to operate with separations between opposed components of less than 1 m;

-    line-type smoke detectors whose optical path length is defined or adjusted by an integral mechanical connection;

-    line-type smoke detectors with special characteristics, which cannot be assessed by the test methods in this document.

NOTE      The term “optical” is used to describe that part of the electromagnetic spectrum produced by the transmitter to which the receiver is responsive; this is not restricted to visible wavelengths.

Edition

3

Published Date

2022-06-13

Status

PUBLISHED

Pages

53

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This document specifies requirements, test methods and performance criteria for line-type smoke detectors for use in fire detection systems installed in buildings. The detectors consist of at least a transmitter and a receiver and can include reflector(s) for the detection of smoke by the attenuation and/or changes in attenuation of an optical beam.

This document is not applicable to:

-    line-type smoke detectors designed to operate with separations between opposed components of less than 1 m;

-    line-type smoke detectors whose optical path length is defined or adjusted by an integral mechanical connection;

-    line-type smoke detectors with special characteristics, which cannot be assessed by the test methods in this document.

NOTE      The term “optical” is used to describe that part of the electromagnetic spectrum produced by the transmitter to which the receiver is responsive; this is not restricted to visible wavelengths.

Previous Editions

Can’t find what you are looking for?

Please contact us at: