ISO 7383:2024 Fine bubble technology – Evaluation method for determining gas content in fine bubble dispersions in water – Part 1: Oxygen content
CDN $115.00
Description
This document specifies evaluation methods for the oxygen content in fine bubble dispersion in water.
Three test methods which are adopted include the optical sensor, the electrochemical probe and the iodometric method. The first two methods have an advantage in availability of in situ and real-time measurement, and high accessibility to commercially available instruments. The last one, composed of a well-established chemical analysis procedure, is advantageous in the situation where the instruments to be used in the first two methods are unavailable.
The detection limits of the electrochemical and optical sensor methods are stated in the instruction manuals of the instruments, in most cases 0,1 mg/l or 0,2 mg/l. The upper limit depends on the specification of the instrument used. Most instruments allow measurement of a supersaturated sample.
Measurement range of the iodometric method is between 0,2 mg/l and 20 mg/l.
NOTE           Chemical analysis methods other than the iodometric method can be applied[1] as an alternative.
Edition
1
Published Date
2024-03-13
Status
PUBLISHED
Pages
12
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
This document specifies evaluation methods for the oxygen content in fine bubble dispersion in water.
Three test methods which are adopted include the optical sensor, the electrochemical probe and the iodometric method. The first two methods have an advantage in availability of in situ and real-time measurement, and high accessibility to commercially available instruments. The last one, composed of a well-established chemical analysis procedure, is advantageous in the situation where the instruments to be used in the first two methods are unavailable.
The detection limits of the electrochemical and optical sensor methods are stated in the instruction manuals of the instruments, in most cases 0,1 mg/l or 0,2 mg/l. The upper limit depends on the specification of the instrument used. Most instruments allow measurement of a supersaturated sample.
Measurement range of the iodometric method is between 0,2 mg/l and 20 mg/l.
NOTE           Chemical analysis methods other than the iodometric method can be applied[1] as an alternative.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 2382:2015 Information technology – Vocabulary
0 out of 5CDN $0.00 Add to cart -
ISO 80004:2011 Nanotechnologies – Vocabulary – Part 7: Diagnostics and therapeutics for healthcare
0 out of 5CDN $115.00 Add to cart -
ISO 80004:2020 Nanotechnologies – Vocabulary – Part 8: Nanomanufacturing processes
0 out of 5CDN $76.00 Add to cart -
ISO 80000:2025 Quantities and units – Part 13: Information science and technology
0 out of 5CDN $203.00 Add to cart