Your cart is currently empty!

ISO 9869:2014
ISO 9869:2014 Thermal insulation – Building elements – In-situ measurement of thermal resistance and thermal transmittance – Part 1: Heat flow meter method
CDN $312.00
Description
ISO 9869-1:2014 describes the heat flow meter method for the measurement of the thermal transmission properties of plane building components, primarily consisting of opaque layers perpendicular to the heat flow and having no significant lateral heat flow.
The properties which can be measured are:
a) the thermal resistance, R, and thermal conductance, Λ, from surface to surface;
b) the total thermal resistance, RT, and transmittance from environment to environment, U, if the environmental temperatures of both environments are well defined.
The heat flow meter measurement method is also suitable for components consisting of quasi homogeneous layers perpendicular to the heat flow, provided that the dimensions of any inhomogeneity in close proximity to the heat flow meter (HFM) is much smaller than its lateral dimensions and are not thermal bridges which can be detected by infrared thermography.
ISO 9869-1:2014 describes the apparatus to be used, the calibration procedure for the apparatus, the installation and the measurement procedures, the analysis of the data, including the correction of systematic errors and the reporting format.
Edition
1
Published Date
2014-07-29
Status
PUBLISHED
Pages
36
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
ISO 9869-1:2014 describes the heat flow meter method for the measurement of the thermal transmission properties of plane building components, primarily consisting of opaque layers perpendicular to the heat flow and having no significant lateral heat flow.
The properties which can be measured are:
a) the thermal resistance, R, and thermal conductance, Λ, from surface to surface;
b) the total thermal resistance, RT, and transmittance from environment to environment, U, if the environmental temperatures of both environments are well defined.
The heat flow meter measurement method is also suitable for components consisting of quasi homogeneous layers perpendicular to the heat flow, provided that the dimensions of any inhomogeneity in close proximity to the heat flow meter (HFM) is much smaller than its lateral dimensions and are not thermal bridges which can be detected by infrared thermography.
ISO 9869-1:2014 describes the apparatus to be used, the calibration procedure for the apparatus, the installation and the measurement procedures, the analysis of the data, including the correction of systematic errors and the reporting format.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 612:1978 Road vehicles – Dimensions of motor vehicles and towed vehicles – Terms and definitions
0 out of 5CDN $173.00 Add to cart -
ISO 80000:2019 Quantities and units – Part 11: Characteristic numbers
0 out of 5CDN $312.00 Add to cart -
ISO 22553:2019 Paints and varnishes – Electro-deposition coatings – Part 1: Vocabulary
0 out of 5CDN $76.00 Add to cart -
ISO 16520:2025 Tourism and related services – Restaurants and catering – Vocabulary
0 out of 5CDN $173.00 Add to cart