Your cart is currently empty!

API MPMS CH 14.7
API MPMS CH 14.7: Mass Measurement of Natural Gas Liquids and Other Hydrocarbons (GPA 8182-18)
CDN $138.57
Description
This document serves as a reference for the selection, design, installation, operation and maintenance of single-phase dynamic liquid mass measurement systems that operate in the 350 to 688 kg/m3 (0.350 to 0.689 relative density at 60°F) density range. The mass measurement systems within the scope of this document include inferred mass measurement, where volume at flowing conditions is combined with density at similar conditions to result in measured mass, as well as Coriolis mass measurement. Liquids with density below 350 and above 688 kg/m3 (below 0.350 and above 0.689 relative density at 60 °F) and cryogenic fluids (colder than approximately –50 °F) are excluded from the scope of this document, but the principles described herein may apply to such streams. Sampling equipment and techniques are covered including standards for analytical methods used to determine the composition of the sampled product. Equations of state and correlations used to calculate the density of the product
Edition
5
Published Date
2018-02-14
Status
Current
Pages
16
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
This document serves as a reference for the selection, design, installation, operation and maintenance of single-phase dynamic liquid mass measurement systems that operate in the 350 to 688 kg/m3 (0.350 to 0.689 relative density at 60°F) density range. The mass measurement systems within the scope of this document include inferred mass measurement, where volume at flowing conditions is combined with density at similar conditions to result in measured mass, as well as Coriolis mass measurement. Liquids with density below 350 and above 688 kg/m3 (below 0.350 and above 0.689 relative density at 60 °F) and cryogenic fluids (colder than approximately –50 °F) are excluded from the scope of this document, but the principles described herein may apply to such streams. Sampling equipment and techniques are covered including standards for analytical methods used to determine the composition of the sampled product. Equations of state and correlations used to calculate the density of the product
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
API MPMS CH 11.2.2: Compressibility Factors for Hydrocarbons: 0.350–0.637 Relative Density (60 degre
0 out of 5CDN $333.90 Add to cart -
API MPMS CH 14.12: Measurement of Gas by Vortex Meters
0 out of 5CDN $168.62 Add to cart -
API MPMS CH 12.1.2: Calculation of Static Petroleum Quantities, Part 2—Calculation Procedures for Ta
0 out of 5CDN $238.74 Add to cart -
API MPMS CH 12.3: Calculation of Volumetric Shrinkage From Blending Light Hydrocarbons with Crude Oi
0 out of 5CDN $175.30 Add to cart