API MPMS CH 9.1: Standard Test Method for Density, Relative Density (Specific Gravity), or API Gravi
CDN $80.14
This publication was last reviewed and confirmed in 2017.
Description
Covers the laboratory determination using a glass hydrometer in conjunction with a series of calculations, of the density, relative density, or API gravity of crude petroleum, petroleum products, or mixtures of petroleum and nonpetroleum products normally handled as liquids, and having a Reid vapor pressure of 101.325 kPa (14.696 psi) or less. Values are determined at existing temperatures and corrected to 15°C or 60°F by means of a series of calculations and international standard tables. The initial hydrometer readings obtained are uncorrected hydrometer readings and not density measurements. Readings are measured on a hydrometer at either the reference temperature or at another convenient temperature, and readings are corrected for the meniscus effect, the thermal glass expansion effect, alternate calibration temperature effects and to the reference temperature by means of volume correction factors; values obtained at other than the reference temperature being hydrometer readings a
Edition
3
Published Date
2012-12-14
Status
Reaffirmed
Pages
18
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
Covers the laboratory determination using a glass hydrometer in conjunction with a series of calculations, of the density, relative density, or API gravity of crude petroleum, petroleum products, or mixtures of petroleum and nonpetroleum products normally handled as liquids, and having a Reid vapor pressure of 101.325 kPa (14.696 psi) or less. Values are determined at existing temperatures and corrected to 15°C or 60°F by means of a series of calculations and international standard tables. The initial hydrometer readings obtained are uncorrected hydrometer readings and not density measurements. Readings are measured on a hydrometer at either the reference temperature or at another convenient temperature, and readings are corrected for the meniscus effect, the thermal glass expansion effect, alternate calibration temperature effects and to the reference temperature by means of volume correction factors; values obtained at other than the reference temperature being hydrometer readings a
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
API MPMS CH 14.3.3: Concentric, Square-Edged Orifice Meters, Part 3—Natural Gas Applications (ANSI/A
0 out of 5CDN $429.06 Add to cart -
API MPMS CH 14.12: Measurement of Gas by Vortex Meters
0 out of 5CDN $168.62 Add to cart -
API MPMS CH 12.1.2: Calculation of Static Petroleum Quantities, Part 2—Calculation Procedures for Ta
0 out of 5CDN $238.74 Add to cart -
API MPMS CH 13.2: Statistical Methods of Evaluating Meter Proving Data
0 out of 5CDN $183.65 Add to cart