REGISTER

FR
Search
×
FR

Placeholder headline

This is just a placeholder headline

API SPEC 14L: Lock Mandrels and Landing Nipples : Reaffirmed

$

273

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 20F: Corrosion Resistant Bolting for Use in the Petroleum and Natural Gas Industries : Reaffirmed

$

169

BUY NOW

Placeholder headline

This is just a placeholder headline

API TR 5NCL Nickel Content Limits for API 5CT Sour Service Products

$

149

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 19ICD: Inflow Control Devices : Reaffirmed

$

189

BUY NOW

Placeholder headline

This is just a placeholder headline

API MPMS CH 23.2: Reconciliation of Liquid Tank Car(s) Quantities : Reaffirmed

$

218

BUY NOW

Placeholder headline

This is just a placeholder headline

API SPEC 16A: Specification for Drill-through Equipment

$

322

BUY NOW

Placeholder headline

This is just a placeholder headline

API RP 13B-2: Field Testing Oil-based Drilling Fluids wA1

$

388

BUY NOW

ISO 10811:2000

ISO 10811:2000 Mechanical vibration and shock – Vibration and shock in buildings with sensitive equipment – Part 2: Classification

CDN $115.00

SKU: faeb9fe07101 Categories: , ,

Description

This part of ISO/TS 10811 defines a method for the classification of shock and vibration in buildings from

measurements in accordance with ISO/TS 10811-1. A classification system of environmental vibration conditions

should serve as guidelines for designers, manufacturers and users of equipment sensitive to shock and vibration,

and for building constructors.

The types of shock and vibration considered are those transmitted from floors, tables, walls, ceilings or isolation

systems into an equipment unit. They can be generated by the following:

a) external sources, for example traffic (by road, rail or air), or building and construction activities such as

blasting, piling and vibratory compaction; the vibration response to sonic booms and acoustical excitations is

also included, as well as weather-induced vibration;

b) equipment for indoor use, such as punch presses, forging hammers, rotary equipment (air compressors, air

conditioner systems, etc.) and heavy equipment transported or operated inside a building;

c) human activities in connection with the service or operation of the equipment, for example, people walking,

especially on raised floors.

The frequency range of interest is normally 2 Hz to 200 Hz. Normally the dominant frequencies are less than

100 Hz because they represent the response of the elements in the building.

This part of ISO/TS 10811 deals only with vibration from a maximum amplitude point of view. The concept of

vibration dose (for example as for estimation of fatigue life) is not treated.

Edition

1

Published Date

2000-06-08

Status

PUBLISHED

Pages

10

Language Detail Icon

English

Format Secure Icon

Secure PDF

Abstract

This part of ISO/TS 10811 defines a method for the classification of shock and vibration in buildings from

measurements in accordance with ISO/TS 10811-1. A classification system of environmental vibration conditions

should serve as guidelines for designers, manufacturers and users of equipment sensitive to shock and vibration,

and for building constructors.

The types of shock and vibration considered are those transmitted from floors, tables, walls, ceilings or isolation

systems into an equipment unit. They can be generated by the following:

a) external sources, for example traffic (by road, rail or air), or building and construction activities such as

blasting, piling and vibratory compaction; the vibration response to sonic booms and acoustical excitations is

also included, as well as weather-induced vibration;

b) equipment for indoor use, such as punch presses, forging hammers, rotary equipment (air compressors, air

conditioner systems, etc.) and heavy equipment transported or operated inside a building;

c) human activities in connection with the service or operation of the equipment, for example, people walking,

especially on raised floors.

The frequency range of interest is normally 2 Hz to 200 Hz. Normally the dominant frequencies are less than

100 Hz because they represent the response of the elements in the building.

This part of ISO/TS 10811 deals only with vibration from a maximum amplitude point of view. The concept of

vibration dose (for example as for estimation of fatigue life) is not treated.