Your cart is currently empty!

ISO 23695:2023
ISO 23695:2023 Water quality – Determination of ammonium nitrogen in water – Small-scale sealed tube method
CDN $115.00
Description
This document specifies a method for the determination of ammonium nitrogen (NH4-N) in drinking water, groundwater, surface water, wastewater, bathing water and mineral water using the small-scale sealed tube method. The result can be expressed as NH4 or NH4-N or NH3 or NH3-N.
NOTE 1   In the habitual language use of sewage treatment and on the displays of automated sealed-tube test photometers or spectrophotometers, NH4 without indication of the positive charge has become the common notation for the parameter ammonium. This notation is adopted in this document even though not being quite correct chemical nomenclature.
This method is applicable to (NH4-N) concentration ranges from 0,01 mg/l to 1 800 mg/l of NH4-N. The measuring ranges of concentration can vary depending on the type of small-scale sealed tube method of different manufacturers. Concentrations even slightly higher than the upper limit indicated in the manufacturers manual relating to the small-scale sealed tube method used, cannot be reported as accurate results. It is up to the user to choose the small-scale sealed tube test with the appropriate application range or to adapt samples with concentrations exceeding the measuring range of a test by preliminary dilution.
NOTE 2   The results of a small-scale sealed tube are most precise in the middle of the application range of the test.
All manufacturers’ methods are based on the Berthelot reaction and its modifications to develop indophenol blue colour. Reagents mixtures can differ slightly based on manufacturers small-scale sealed tube method, see Clause¬†9. This method is applicable to non-preserved samples by using small-scale sealed tubes for the determination of drinking water, groundwater, surface water, wastewater and to preserved samples. The method is applicable to samples with suspended materials if these materials are removable by filtration.
Edition
1
Published Date
2023-02-02
Status
PUBLISHED
Pages
12
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
This document specifies a method for the determination of ammonium nitrogen (NH4-N) in drinking water, groundwater, surface water, wastewater, bathing water and mineral water using the small-scale sealed tube method. The result can be expressed as NH4 or NH4-N or NH3 or NH3-N.
NOTE 1   In the habitual language use of sewage treatment and on the displays of automated sealed-tube test photometers or spectrophotometers, NH4 without indication of the positive charge has become the common notation for the parameter ammonium. This notation is adopted in this document even though not being quite correct chemical nomenclature.
This method is applicable to (NH4-N) concentration ranges from 0,01 mg/l to 1 800 mg/l of NH4-N. The measuring ranges of concentration can vary depending on the type of small-scale sealed tube method of different manufacturers. Concentrations even slightly higher than the upper limit indicated in the manufacturers manual relating to the small-scale sealed tube method used, cannot be reported as accurate results. It is up to the user to choose the small-scale sealed tube test with the appropriate application range or to adapt samples with concentrations exceeding the measuring range of a test by preliminary dilution.
NOTE 2   The results of a small-scale sealed tube are most precise in the middle of the application range of the test.
All manufacturers' methods are based on the Berthelot reaction and its modifications to develop indophenol blue colour. Reagents mixtures can differ slightly based on manufacturers small-scale sealed tube method, see Clause 9. This method is applicable to non-preserved samples by using small-scale sealed tubes for the determination of drinking water, groundwater, surface water, wastewater and to preserved samples. The method is applicable to samples with suspended materials if these materials are removable by filtration.
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
ISO 14911:1998 Water quality – Determination of dissolved Li+, Na+, NH4+, K+, Mn2+, Ca2+, Mg2+, Sr2+ and Ba2+ using ion chromatography – Method for water and waste water
0 out of 5CDN $173.00 Add to cart -
ISO 9964:1993 Water quality – Determination of sodium and potassium – Part 2: Determination of potassium by atomic absorption spectrometry
0 out of 5CDN $76.00 Add to cart -
ISO 21675:2019 Water quality – Determination of perfluoroalkyl and polyfluoroalkyl substances (PFAS) in water – Method using solid phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS)
0 out of 5CDN $312.00 Add to cart -
ISO 21793:2020 Water quality – Determination of total organic carbon (TOC), dissolved organic carbon (DOC), total bound nitrogen (TNb), dissolved bound nitrogen (DNb), total bound phosphorus (TPb) and dissolved bound phosphorus (DPb) after wet chemical catalysed ozone hydroxyl radical oxidation (COHR)
0 out of 5CDN $273.00 Add to cart