Your cart is currently empty!

API TR 17TR9
API TR 17TR9: Umbilical Termination Assembly (UTA) Selection and Sizing Recommendations
CDN $202.01
Description
This technical report identifies and describes: — technical, commercial, and installation risks associated with high-functionality umbilicals and umbilical terminations [resulting in large and heavy umbilical termination assemblies (UTAs)], especially with respect to installation; — implications of decisions made early in the umbilical and subsea umbilical termination (SUT) planning, selection, and design phases, to ease the manufacturing, handling, and final umbilical/UTA installation; — guidance on specification and sizing of umbilical terminations, including overall size, weight, and handling requirements. This document acts as a reference guide during the early field development planning stage to ensure that due consideration is given to the implications of the size of UTAs and possible consequences during installation. It is intended to be used as a reference guide by end users and operators, UTA and umbilical manufacturers, installers, and front-end engineering design (FEED) com
Edition
1
Published Date
2017-08-01
Status
Current
Pages
52
Format 
Secure PDF
Secure – PDF details
- Save your file locally or view it via a web viewer
- Viewing permissions are restricted exclusively to the purchaser
- Device limits - 3
- Printing – Enabled only to print (1) copy
See more about our Environmental Commitment

Abstract
This technical report identifies and describes: — technical, commercial, and installation risks associated with high-functionality umbilicals and umbilical terminations [resulting in large and heavy umbilical termination assemblies (UTAs)], especially with respect to installation; — implications of decisions made early in the umbilical and subsea umbilical termination (SUT) planning, selection, and design phases, to ease the manufacturing, handling, and final umbilical/UTA installation; — guidance on specification and sizing of umbilical terminations, including overall size, weight, and handling requirements. This document acts as a reference guide during the early field development planning stage to ensure that due consideration is given to the implications of the size of UTAs and possible consequences during installation. It is intended to be used as a reference guide by end users and operators, UTA and umbilical manufacturers, installers, and front-end engineering design (FEED) com
Previous Editions
Can’t find what you are looking for?
Please contact us at:
Related Documents
-
API RP 10B-5: Recommended Practice on Determination of Shrinkage and Expansion of Well Cement Formul
0 out of 5CDN $156.93 Add to cart -
API SPEC 10F: Errata 2
0 out of 5CDN $0.00 Add to cart -
API RP 1145: Preparation of Response Plans for Oil Spills from Offshore Facilities
0 out of 5CDN $235.40 Add to cart -
API SPEC 11AX: Addenda 1
0 out of 5CDN $0.00 Add to cart